Studiosorba

STUDIOSORBA™ sound absorbers work by vibrating with the acoustic energy in the room, converting it into heat and preventing it from being reflected back into the room which would otherwise cause interference.

The STUDIOSORBA™ range of products include Disc Absorbers, Wedge Absorbers, Pyramid Absorbers, Corner Bass Absorbers and Cube/Rectangular Absorbers.

Digitally printed acoustic panels

Studiosorba

Sound Absorbers

  • Product Description
  • Acoustic
  • Installation
  • Technical

 

STUDIOSORBA™ sound absorbers have been specifically developed for the treatment of echo and reverberation in a number of areas, primarily studios and music rooms but they are also used in schools, offices and other areas.

Television and music studios require specialist acoustic treatment to cater for high quality listening of music and speech.

 

Many such rooms tend to be 'boomy' and require bass absorbers to absorb such low frequency sound as well as middle and high frequencies

Acoustic Performance

Disc Absorbers
  Frequency (Hz)
125
250
500
1000
2000
4000
NRC
  Absorption 50mm
0.12
0.20
0.47
0.73
0.96
0.91
0.60
  Absorption 100mm
0.23
0.48
0.82
0.98
1.02
1.04
0.83
 
Wedge Absorbers
  Frequency (Hz)
125
250
500
1000
2000
4000
NRC
  Absorption 50mm
0.12
0.31
0.90
1.04
1.00
1.02
0.81
  Absorption 100mm
0.30
0.86
1.26
1.16
1.08
1.10
1.09
                 
Pyramid Absorbers
  Frequency (Hz)
125
250
500
1000
2000
4000
NRC
  Absorption 50mm
0.13
0.20
0.58
0.96
1.04
0.97
0.70
  Absorption 100mm
0.26
0.51
1.00
1.12
1.10
1.11
0.93
 
Corner Bass Absorbers
  Frequency (Hz)
125
250
500
1000
2000
4000
NRC
  Absorption
1.20
1.25
1.40
1.35
1.24
1.27
1.31

 

 

They are lightweight and can be installed to both walls and ceilings using Soundsorba's Gluesorba spray can adhesive.

 

Please refer to and work from the installation details given in the product brochure.

Fire Resistance

Meets the requirements of The Furniture and Furnishings (Fire Safety) Amended Regulations 1989 Schedule 1 Part 1. From which meets Class 1 and Class 0 of BS 476 Part 6 and 7 may be available on request.

Dimensions

Density Range - 38 - 42kg/m²
Hardness Range - 145 - 185 Newton's
Tensile strength - 70KPa (minimum)
Elongation at break - 150% min